Description: Firestone RubberGard 5' x 80' 45-Mil EPDM Roofing Rubber - FS05X80-45 Firestone RubberGard 5' x 80' 45-Mil EPDM Roofing Rubber - FS05X80-45 Based on a high-performance synthetic rubber compound, RubberGard EPDM membrane exhibits outstanding resistance to UV radiation, the ozone, and weathering from the elements on rooftop installations. RubberGard EPDM provides excellent low temperature properties and longer service life. With an environmentally-aware membrane that is recyclable in many situations, the system’s thermal-performance may reduce energy consumption. Firestone RubberGard EPDM Roofing Rubber Liner system can be fully adhered, ballasted, and mechanically attached during installation. Contractors, building owners, architects, and specifiers have trusted Firestone Building Products for superior commercial roofing systems for nearly 30 years. Firestone RubberGard EPDM Roofing Rubber Liner can be applied, anytime, YEAR-ROUND! You can trust Firestone! Contractors, building owners, architects, and specifiers have trusted Firestone Building Products for superior commercial roofing systems for nearly 30 years. With billions of square feet installed globally, and with a commitment to environmentally-friendly initiatives, Firestone has become the preferred supplier of roofing systems throughout the world! Firestone RubberGard 5' x 80' 45-Mil EPDM Roofing Rubber - FS05X80-45 45-Mil Liner: The Most Popular Material for New And Re-Roof, Low Slope, Roofing Applications Outstanding Durability And Low Life Cycle Cost Means Excellent Value Easily Contours to Unusual Roof Shapes. Perfect for Do-It-Yourself Homeowners or Roofing Contractors Flexible Material Allows Design Versitility and Easy Installation NOTE: If using for a deck or a roof, make sure you order a liner size slightly larger than your dimensional needs. We don't want to sell you more than you need, but getting an EXACT size will not be sufficient to cover your deck or roof correctly. FAQs About Firestone RubberGard 1. What is EPDM? EPDM is an elastomeric compound that is manufactured from ethylene, propylene, and a small amount of diene monomer. These ingredients are synthesized to produce a product that exhibits a high degree of ozone, ultraviolet, weathering and abrasion resistance, and outstanding low temperature flexibility. These ingredients also contribute to resistance to acids, alkalis, and oxygenated solvents (i.e. ketones, esters, and alcohols). 2. What is the maximum size sheet for EPDM membrane? Sheets as large as 50 feet in width are produced mostly for use in ballasted and mechanically fastened applications. Narrower widths are also produced to offer applicators greater flexibility in positioning membrane. Narrower sheets are also produced without factory seams (seamless) for use primarily in adhered and mechanically fastened applications. The major advantage of seamless material is the elimination of factory splice T-joints that occur when factory seams intersect with field splices. This reduction in T-joints significantly increases the potential for watertight performance by eliminating potential "water channels" into field splices. Both narrow and wide sheets are manufactured in varying lengths from 50' to 200'. 3. Are temperature limitations associated with the installation of EPDM roofing system? In accordance with ASTM standard D 746, EPDM membrane has a brittleness temperature of -49° F. While the membrane will remain flexible and pliable in extremely cold temperatures, adhesives, flashings and tapes should be kept at room temperature (hot boxes are usually used on the rooftop to rotate adhesive cans and rolls of flashing). Although roofing contractors may select not to work in sub-freezing temperatures due to safety concerns, many EPDM installations have taken place in temps below 20° F. 4. Can EPDM be coated or painted? Acrylic coatings are available that can be applied directly to a prepared EPDM surface. Preparation usually consists of cleaning the EPDM with a pressure washer and a detergent solution or wash. Latex-based paint products can also be used, however, the EPDM manufacturer should be contacted prior to application to ensure compatibility and continuation of warranty coverage. 5. How do I seam 2 pieces of liner together? There are seam tapes like 3 inch double sided seam tape to seam to sheets of rubber together. There is also 6 inch and 12 inch flashing for detail work around vents, air conditioning and ventilation units and other large penetrations. There is also a rubber pipe boot for pipe penetrations that fits 1 inch up to 6 inch pipes. About Triumph Global's Roof Shop Customer service is our business. Welcome to Triumph Global Roofing Rubber. We are one of the largest distributors of Firestone RubberGard and have over 25 years of experience! Thanks for your business! We appreciate it! - The Triumph Global Team
Price: 508 USD
Location: O'Fallon, Missouri
End Time: 2024-10-09T17:04:29.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Return policy details:
Brand: RubberGard
Type: Roofing Rubber
Material: EPDM Rubber
Suitable For: Roof Space
Fire Rating: A1
Item Length: 80 ft
Item Width: 5 ft
Coverage: 400 sq. ft
Features: UV Protection
Item Thickness: 45 mil
Model: FS05X80-45
MPN: FS05X80-45
Number in Pack: 1
Country/Region of Manufacture: United States
Item Weight: 120 lb
Manufacturer Warranty: 25 Years
Unrolled Length: 80 ft
Subject Area: Roofing