Description: Notice: This tips only fit for EASYINSMILE Endo Irrigator Activator https://www.ebay.com/itm/303773445989 Package List: Needle Tips: 2/15 20 PC 4/25 20 PC 4/35 20 PC Dental Endo Activator Tip Sonic Irrigator Root Canal Cleaning 60 Tips No Breakendodontic irrigatorNotice: This tips only fit for EASYINSMILE Endo Irrigator Activator Package List:Needle Tips:2/15 20 PC4/25 20 PC4/35 20 PC 1. Indications For userThe Easydo Activator system uses technology of sonic energy for root canal treatment. The driver work with the Hand device, motor and needle tip to provide power for tip oscillation and vibration. Evidence-based endodontics has shown that cavitation and acoustic streaming can improve debridement and the disruption of the smear layer and biofilm.The Activator helps the fluids streaming enter the Pulp Chamber, Root Canal, Lateral canal, Connection of inter-root canal and root apex to ensure deep cleaning and sterilization of root canal. It is beneficial to complete the 3D filling of the root canal and ensures long-term success.2. Notice1) Remove the needle tip of EasyDO Activator. If your treatment process isover, please leave it for medical recycling.2) Please put exhaustively discharged battery into the recycling box.3)Do not submerge the unit in water.4)Do not autoclave the unit.3. Precautions1) The EasyDO Activator system is only used by dental professionals.2) The EasyDO Activator system is comprised of the Hand device and Activator needle tips of various sizes. If the system functions are used correctly, the equipment can maintain a normal operation. It is strictly prohibited to use non-original components, which will damage the equipment and make it unable to work normally. The original components include the Easydo activator hand device, needle tip and protective cover.The Easy smile reference number of the hand device EASYDO Activator-M10821The reference numbers of the EasyDOActivator Needle tipM10822-015 (Small)M10822-025 (Medium)M10822-035 (Large) 3)The handle device provides three speeds sonic motor adjustment options(High, Med, Low). The speed gears switch setting adjustment is ultimatelydetermined by the procedure to be performed, the cliniclan' experience canefficiently complete the clinical task.4) The handle device don’t require calibration for normal use.5) All clinical treatment should be performed with Easydo activatorprotective barrier sleeve that placed over the hand device.6) In the course of treatment, we should use sterilized and individuallypacked needle tip, otherwise it will cause root canal infection.7) It is necessary to use EasyDO Activator system correctly according totreatment specifications and operation manual to prevent injury to patients.8) Improper using of the hand device may result in broken handle of theequipment and damage of internal components.9) The EasyDO Activator needle tips and protective sleeve are intended forsingle-patient use only. Cross contamination may occur to the patient ifneedle tips and protective barriers are re-used. 4. Warranty information of EasyDO activator1)The EASY IN SMILE company provides users with quality assurance within one year from the date of purchase of this product. In case of anyfailure due to the defect of Hand device material or production process of the mainframe within this year, the EASY IN SMILE company will provide equipment repair or replacement products.2)The warranty does not include consumables such as needles, batteries, etc.3)If the equipment is damaged due to improper use and maintenance,or maintenance personnel repair or change of spare parts without theauthorization of EASY IN SMILE, the warranty policy is invalid.4)Under any condition, neither EASY IN SMILE nor its affiliates areresponsible for any special, incidental, or consequential liabilityresulting from a violation of the warranty policy, contract, or any otherlegal policy. Such damages include but are not limited to loss ofinvestment, loss of profits, loss caused by wrong use of productfunctions, etc.; including but not limited to third party claims andincrease of service cost caused by any alternative equipment, etc. 5)Warranty limitationsContent not covered by warranty:-Needle tip-Hand device barrier sleeve-Damage caused by misuse, abuse, neglect of prompt or change of theequipment usage-Normal wear and other external scratches, including scratches, wear,cracks, discoloration or fade.-Battery replacement* Note:If the product is not used for a long time (two weeks or longer), pleaseremove the battery. It also must be removed during transport, forexample, during delivery10) Properly dispose the Activator needles tip and hand device protectivebarriers in accordance with the local laws and regulations and environmentalprotection requirements.11) Dispose the battery after being used in accordance with the local lawsand regulations and environmental protection requirements, when battery isexhausted.12) The hand device must be repaired if necessary according to the directionof the manufacturer.13) Don’t insert needle tip into the hand device. If the equipment is not usedfor a long time, placing the hand device into packing box is recommended.14) Remove the battery when the hand device is not used for a long time.15) The hand device can be kept at the temperature of 0 ℃ ~ 55 ℃,relative humidity 0% ~ 75% RH and air pressure750-1060 HPA.16) The hand device should be keep away from strong electromagneticinterference, which may affect the performance and normal use of handdevice.17) The hand device should be kept away from portable or mobile RFcommunication devices, which may affect the performance of hand device .18) The hand device could not be adjacent to or stored with other equipment.In addition, it is necessary to check regularly whether the hand device canwork normally.19) Proper disposal of the hand device is required when the hand pieceis deemed no-functional in accordance with local laws and regulations.6.Product parametersNameEasyDO ActivatorModelEASYDO Activator-M1082FunctionDebridement / disinfection / root canal therapyUse environmentIndoor environment; Temperature range: 0 ℃ ~ + 55 ℃; RelativeHumidity: 0% ~ 75% RH; Air Pressure: 750-1060 HPAPower SupplyDC:1.0v~1.5vBatteryAA grade LR6, 1.5v mercury-free alkaline dry batterySizeL 183mm * W 23mm * H43.1mmGross Weight124g7.Operation / StepPreparation:1) Prepare the root canal to produce a fully tapered shape.2) Fill pup chamber with NaOCI, EDTA, or final rinse soulution.3) Select the needle tip that manually fits loosely within 2mm of theworking length.4) Place the barrier sleeve over the complete length of the hand device.5) Connect the needle tip to the hand device with the barrier sleeve. Theactivator should snap on firmly, promoting a secure connection with thehand device.6) Press ON/OFF button for 1 second, you can see the battery powerstatus. If the power is enough, you can continue the treatment. If thepower is not enough, you need to replace the battery.7) Place the attached needle tip into the prepared root canal.8) Drepress the ON/OFF button to actvate. Switch defaults to high speedupon activation. Depress the 3-speed switch to select medium speed orlow speed.9) Use a pumping action to move the hand device in short 2~3 mmvertical strokes.10) Hydro dynamically agitate the medical solution for about 30-60seconds.11) After washing, use a suction pipe to remove loose debris andsundries from the root canal.12) Repeat the above steps for each different root canal treatment.* when the clinical procedure has been completed, remove theprotective barrier sleeve, remove the needle tip and store it in the medical waste recycling box. The needle tip and protective sleeve areintended for single-patient used only.Other instructions: if the EasyDO Activer hand device has been workingfor 8 minutes without any operation, or there is no operation after theequipment stops working, it will enter the state of self-protectionsystem and power oFF. If you need it to restart , please depress theON/OFF switch.8. Key points of Operation:5.1)POWER OF BATTERY STATUSDepress the " ON / OFF Switch" key for 1 second to observe the "PowerIndicator" status around the button of the hand device.1. If the "Power Indicator" is white, it means the activator system is infull power status;2. if the "Power Indicator" is red and white, it means the system is inhalf power status;3. if the "Power Indicator" is red, it means the system is in powershortage status; 4. If the "Power Indicator" is flashing red, it indicates that the system ison the verge of power failure.5. Please note if the "power indicator" is flashing red, please replace thebattery. FDA DescriptionDelivery detailsTerms of salesPaymentFAQFDA DescriptionThe sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.USA CHIEF OFFICE: EASYINSMILE(USA)INTERNATIONAL CORP.CHINA FACTORY: CHANGSHA EASYINSMILE MEDICAL INSTRUMENT CO LTDAddress: Room A501, A502, A504, Jinqiyuan Incubation Mansion, No. 229410000 ChangshaChinaPhone:0086-18373188632 Easyinsmile(USA)International Corp. is a professional Large-scale Manufacturer of all types of dental instruments and related products,integrating development and production.Our company regards"Reasonable prices,efficient production time and good after sale service" as our tenet.We hope to cooperate with more customers for mutual development and benefits.We welcome potential buyers to contact us.Delivery details1. The parcel will be posted within 1-3 working days after payment received.2. Please be advised that some items aren’t ship-able to P.O.Box because the size of the package.3. USPS, FexEx, UPS for USA warehouse shipping. DHL eCommerce, ePacket, DHL express, China Post, EMS for China warehouse.4. Please contact us first, if you need a fast/special shipping methods.5. 3-5 days for USA shipping. If you didn’t receive the item within 2 weeks, please contact us. We’ll check it for you.6. About 25-28 days in generally for International shipping. Please check the shipping information online or leave us a message, if you didn’t receive the parcel within 28 day. We’ll check it for you.7. We have local warehouse in the USA, AU and UK, you can go to your local website to purchase. Then we'll ship for you from the local warehouse, if they are in stock for local warehouse. Tips: 1. Some time the parcel will deliver in the Mail Box/P.O.Box. Please check it with the shipping information online. (USA shipping)2. Some local post office does not provide the delivery service, you may need go to the local post office to get the parcel. Please understanding. (International shipping)3.Any problems, welcome to leave us a message. We’ll help you. Delivery Time Terms of salesAbout Warranty: We guarantees new equipment other than accessories to be free from defects in workmanship and materials for a period of twelve months (six months for spare parts) from the date of shipment under normal use and service. Our company's obligation under this warranty is limited to repairing, at our company's option, any part which upon our company's examination proves defective. Return Policy If you receive a defective item which you want to return, please contact us within 2 days from the day you receive the item. All return items must be returned with its original packaging and accessories. If we confirm the damage happened during the shipment, we will bear the shipping cost for return.We will refund the money to you when we get the return items. Or replace item for you free of charge. Statement: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and stateand local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser.If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of thisitem before shipping of the item. PaymentWith Paypal,you can pay easily,quickly and securly. Please pay as soon as possible if you like the products,as that will allow us to post your item to you sooner. FAQWe always go for 100% customer satisfaction. Positive feedback means a lot to us.If you have any queries, please contact us via eBay. We will reply you as soon as possible.We will appreciate it if you please email us before leaving any negative feedback. If there is any problem, we can work together to resolve it.Q: Do you ship the parcel with a tracking number?A: We always ship the items with a tracking number and you can check the shipping information online.Q: I’m in the US. When does the parcel come?A: About 3-5 days in generally. You can contact us to check the shipping information, if you didn’t get it in 2 weeks. (Sometimes will deliver in the mail box *^__^* ) Q: I’m an international buyer. How long does the parcel reach my address?A: About 18-28 days in generally. You can leave us a message where you are, we can check it for you. (●^o^●)Q: Why does the parcel return back to the sender?A: Sometimes the parcel was in the local post office for a long time and unable to delivery, or unclaimed, or an ambiguous delivery address, or wrong delivery details.The parcel will be back to us. Do not worry. If you didn’t receive the parcel, we can resend or refund you as your request.Q: Why does your price more expensive than others?A: We always believe that the price fit the quality. And we believe that better quality and better service will make you and your customer more satisfied.Q: I received the wrong items. What happened?A: Please do not worry. Just leave us a message and send us a photo about items and shipping label. We’ll help you.Q: The item damaged on arrival. Could you please resend/refund me?A: Yeah, friend. We can refund/resend. Not forget send us a photo to check. 。◕ᴗ◕。Q: I want to buy several items. Could you give me a discount?A: Why not? Add all the items you need to your cart, you can get a discount automatically.Q: What type of discount do you provide?A: We provide many types of discount. You can choose the one that suits you best with the following linkhttps://www.ebay.com/sme/easyinsmile-dental/offers.html
Price: 35.99 USD
Location: Rowland Heights, California
End Time: 2023-12-21T18:22:37.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Brand: Easyinsmile
Country/Region of Manufacture: China
Intended Use/Discipline: Dental Laboratory, Dentistry, Endodontics, Orthodontics
MPN: Does not apply
Model: endo irrigator activator tips
Ultrasonic Scaler Type: handheld
Warehouse: USA/China
Custom Bundle: Yes
Bundle Description: Easyinsmile package