Di-Acro

Hioki 3169-20 Clamp On Power HiTester Power Quality Analyzer 3169

Description: The Following Items Are Included: Hioki 3169-20 Clamp On Power HiTester (BC# 29373-L/T*)  (4) Hioki 9661 Clamp-On Sensors (4) Hoioki Test Leads Hioki 32MB Flash Card w/ Adapter Power Cord User Manual On Cd-ROM Carrying Case (G) BE SURE TO CHECK OUR EBAY STORE FOR OTHER ITEMS! This Item Has A Current Calibration! Hioki 3169 Clamp On Power HiTester Power Quality AnalyzerIn addition to measuring standard parameters such as voltage, current, power, power factor, and integrated values, these clamp-on power meters can simultaneously perform demand measurements required for carrying out power management and energy-saving measures, as well as harmonic measurementsIdeal For Power and Harmonics ManagementIncludes (4) Hioki 9661 Clamp-On Sensors, Carrying Case & Accessories As Listed Above!     Working Condition: ExcellentCondition: RefurbishedCalibrated: YesWarranty: 1 YEAR WARRANTY   Hioki 3169-20 Clamp-On Power HiTesterCLAMP ON POWER HiTESTERs are 3169-20 that allow measurement of single-phase to three-phase 4-wire circuits with a single unit. In addition to measuring standard parameters such as voltage, current, power, power factor, and integrated values, these clamp-on power meters can simultaneously perform demand measurements required for carrying out power management and energy-saving measures, as well as harmonic measurements. The two new power meters also feature PC card data storage, and come equipped with an RS-232C interface for PC communications. Further, with greater data processing speeds, it is possible to measure the power of just a few cycles, enabling more detailed and effective energy-saving measures for equipment. The 3169-20 and 3169-21 are ideal for users who want to achieve close control over energy-saving management activities and measures.Features: Measure power lines of up to four systems (with a common voltage) A wide range of measurement functions Equipped with ranges from 0.5 A to 5000 A Supports high-speed data storage from individual waveforms PC Card compatible plus internal hard drive for extra memory Housed in a compact A5 body size Multi-language Compatibility Detect incorrect connection using vector diagrams Polarity display and measurement using the reactive power measurement method High-speed D/A output Ideal for power and harmonics management Range Configuration Table: CLAMP ON SENSOR 9661 (5A, 10A, 50A, 100A, 500A) Connection 5.0000A 10.000A 50.000A 100.00A 500.00A 150.00V Single-phase 2-wire 750.00 W 1.5000kW 7.5000kW 15.000kW 75.000kW Single-phase 3-wire 1.5000kW 3.0000kW 15.000kW 30.000kW 150.00kW Three-phase 3-wire Three-phase 4-wire 2.2500kW 4.5000kW 22.500kW 45.000kW 225.00kW 300.00V Single-phase 2-wire 1.5000kW 3.0000kW 15.000kW 30.000kW 150.00kW Single-phase 3-wire 3.0000kW 6.0000kW 30.000kW 60.000kW 300.00kW Three-phase 3-wire Three-phase 4-wire 4.5000kW 9.0000kW 45.000kW 90.000kW 450.00kW 600.00V Single-phase 2-wire 3.0000kW 6.0000kW 30.000kW 60.000kW 300.00kW Single-phase 3-wire 6.0000kW 12.000kW 60.000kW 120.00kW 600.00kW Three-phase 3-wire Three-phase 4-wire 9.0000kW 18.000kW 90.000kW 180.00kW 900.00kW FLEXIBLE CLAMP ON SENSOR 9667 Connection 500.00 A 5.0000kA 150.00V Single-phase 2-wire 75.000kW 750.00kW Single-phase 3-wire 150.00kW 1.5000MW Three-phase 3-wire Three-phase 4-wire 225.00kW 2.2500MW 300.00V Single-phase 2-wire 150.00kW 1.5000MW Single-phase 3-wire 300.00kW 3.0000MW Three-phase 3-wire Three-phase 4-wire 450.00kW 4.5000MW 600.00V Single-phase 2-wire 300.00kW 3.0000MW Single-phase 3-wire 600.00kW 6.0000MW Three-phase 3-wire Three-phase 4-wire 900.00kW 9.0000MW Specifications: Basic Specifications: Measurement line type Single-phase 2-wire, single-phase 3-wire, three-phase 3-wire, and three-phase 4-wire systems (50/60 Hz) Number of systems that can be measured (for systems that share the same voltage) Single-phase: 1P2W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 systems 1P3W . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 systems Three-phase: 3P3W2M (measures the voltage and current for two lines) . . . . . . 2 systems 3P3W3M (measures the voltage and current for all three lines) . . . 1 system 3P4W (measures the voltage and current for three lines) . . . . . . . . 1 system 3P4W4I . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 system Item Voltage, current, active power, reactive power, apparent power, power factor, integrated value, frequency, harmonics Measurement range For the voltage, current, and active power ranges, see the range configuration tables Measurement method : Simultaneous digital sampling of voltage and current, PLL synchronization or a fixed clock (50/60 Hz) Input methods Voltage: Isolated input Current: Isolated input using a clamp-on sensor Effective measurement area Within 5 to 110% of the range Total display area Voltage and current: Within 0.4 to 130% of the range  (zero is suppressed for less than 0.4%) Power: Within 0 to 130% of the range  (zero is suppressed when the voltage or current is zero)Harmonic level: Within 0 to 130% of the range Display 5.7-inch LCD (320 × 240 dots), with backlight Range switching method Manual (the current range can be set for each system) Display update rate Approx. every 0.5 seconds  (except when using a PC card while accessing the internal memory, or when performing RS-232C communications) Input resistance (50/60 Hz) Voltage: 2.0 MΩ ± 10% (differential input) Current: 200 kΩ ± 10% Maximum input Voltage input: 780 Vrms AC, peak value: 1103 V Current input: 1.7 Vrms AC, peak value: 2.4 V Maximum rated voltage to earth Voltage input terminals: 600 Vrms AC (50/60 Hz) Crest factor Voltage: Less than 2 (for full-scale input) Current: Less than 4 (for full-scale input. However, less than 2 for the 500 A, 1 kA, and 5 kA ranges) Internal memory capacity 1MB Display Specifications Instantaneous value display Voltage, current, active power, reactive power, apparent power, power factor, frequency, average voltage, average current, (average values are for each system) Average value display Voltage, current, active power, reactive power, apparent power, power factor, frequency, average voltage, average current Maximum/minimum value display Voltage, current, active power, reactive power, apparent power, power factor, frequency Integrate display Integrated valueActive power (consumption/regeneration)Reactive power (lag/lead) Demand volume display(Integrated value within the specified interval) Integrated value Active power volume (consumption/regeneration)  Reactive power volume (lag/lead) Demand value display(average value within the specified interval) Active power (consumption), reactive power (lag), power factor Maximum demand value display(average value within the maximum specified interval) The maximum demand value since the beginning of time series measurement and the time and date it occurred. Harmonics list List of the items measured for the specified harmonic (numerical value). Harmonics graph Bar graph or vector diagram of the items measured for the specified harmonic Waveform display Voltage and current waveforms (with a magnification update function) Measurement value enlargement display Select and enlarge up to 5 items from the instantaneous value display. Measurement Specifications Measurement method True RMS method Measurement display Measurement of three voltage lines and 3 or 4 current lines is possible when using three-phase 3-wire and three-phase 4-wire systems Measurement display For three-phase 3-wire (the 3P3W3M setting), refer to the display for phase power values. Polarity display For consumption: no symbol, for regeneration: "-" [Reactive power measurement]Using the reactive  ON: Measures the reactive power directly using the reactive power measurement method OFF: Calculates the reactive power from the measurement values for voltage, current, and active power Polarity display For lag phase (LAG : current is slower than voltage): no symbol For lead phase (LEAD: current is faster than voltage) : "-" (Reactive power measurement method "ON") [Apparent power measurement]Polarity display No polarity [Power factor measurement]Measurement range 1.0000 (lead) to 0.0000 to +1.0000 (lag)For lag phase (LAG: current is slower than voltage) :no symbol For lead phase (LEAD: current is faster than voltage) : "-" Measurement range 40.000 to 70.000 Hz Input area for guaranteed accuracy Within 10 to 110% of the range (for sine wave input) Measurement source  Voltage U1 Measurement range 40.000 to 70.000 Hz Input area for guaranteed accuracy Within 10 to 110% of the range (for sine wave input) Measurement source Voltage U1 [Integrated measurement]Measurement range Active power : 0.00000 mWh to 99999.9 GWh consumption -0.00000 mWh to -99999.9 GWh regeneration Reactive power : 0.00000 mvarh to 99999.9 Gvarh lag -0.00000 mvarh to -99999.9 Gvarh lead Measurement display Active power : Displays consumption and regeneration separately Reactive power : Displays lag and lead separately [Harmonic measurement]Measurement range Basic wave frequency: 45 to 66 Hz PLL synchronization Order for analysis Up to the 40th order Window width A single cycle (number of data points analyzed: 128 points) Window type Rectangular Analysis rate 1/16 cycles Item for analysis Harmonic level: The voltage, current, or power level for each harmonic order: Harmonic content percentage: The voltage, current, or power content percentage for each harmonic order: Harmonic phase angle: The voltage, current, or power phase  angle for each harmonic order: Total value: The total value for voltage, current, or  power up to the 40th harmo Setting Specifications Measurement line settings 1P2W, 1P3W, 3P3W2M, 3P3W3M, 3P4W, 3P4W4I Clamp-on sensor settings 9694, 9660, 9661, 9667, 9669, 9695-02 and 9695-03 (* A different sensor can be set for each system.) VT (PT) and CT ratio settings 0.01 to 9999.99 (* A different CT ratio can be set for each system.) Measurement start method Manual or time (year, month, day, hour, minute) Measurement stop method Manual, time, or timer (1 seconds to 8784 hours) Output Interval Standard or fast (*Maximum measurement period: 1 year) Standard interval: 1, 2, 5, 10, 15, or 30 seconds, or 1, 2, 5, 10, 15, 30, or 60 minutes Fast interval: A single waveform, or 0.1, 0.2, or 0.5 seconds Data output destination PC card, internal memory, or printer File name Automatically attached, or set the desired name (up to 8 alphanumeric characters) Display averaging circuit OFF, 2, 5, 10, 20 times (for movement averaging) Screen copy destination PC card, internal memory, or printer Display language settings Japanese, English, German, French, Italian, Chinese (Simple, Trad), Spanish , Korean Other settings Reactive power measurement method selection, harmonic distortion selection, order display selection, backlight settings, ID settings, clock settings, etc. Copy file Copies files from the internal memory to the PC card Load/Save selected file  Loads/Saves the file(s) selected from the internal memory or PC card Delete file Deletes the file(s) from the PC card Format Initializes the PC card or internal memory. Storage format Measurement data: CSV format (binary format when using the fast interval setting) Waveform data: Binary format Screen data: BMP format Settings data: CSV format Instantaneous values Voltage, current, active power, reactive power, apparent power, power factor, frequency, average voltage, average current, (average values are for each system) Average value Voltage, current, active power, reactive power, apparent power, power factor, frequency, average voltage, average current, (average values are for each system) Maximum/minimum value Voltage, current, active power, reactive power, apparent power, power factor, frequency Integrated value Active power (consumption/regeneration) Reactive power (lag/lead) Demand value Active power (consumption), reactive power (lag), power factor Maximum demand value The maximum demand value since the beginning of time series measurement and the time and date it occurred. Harmonic : Each harmonic order (level, content percentage, and phase angle), total value, instantaneous value for THD-F/THD-R: Each harmonic order (level, content percentage, and phase angle), total value, average value for THD-F/THD-R for each interval: Each harmonic order (level, content percentage, and phase angle), total value, maximum/minimum value for THD-F/THD-R within each interval Waveform Waveform (Voltage or current) Status information Exceeds the voltage/current crest factor, PLL unlock, power failure, exceeds the display limit Numerical values Prints the data selected as the data output item (during time series measurement). Waveform Hard copy of the screen (printing of each interval not available) General Specifications Operating environment Indoors, up to 2000m(78.74ft) ASL Operating temperature and humidity 0 to 40˚C, 80% RH or less (non-condensating) Storage temperature and humidity -10    to    50˚C,    80%    RH    or    less    (non-condensating) Withstand voltage  (50/60 Hz for 15 sec.) 5.55 kVrms AC: Between the voltage input terminal and the 3169 casing 3.32 kVrms AC: Between the voltage input terminal and the current input terminal/external interface terminal 2.3 kVrms AC: Between the power supply and the 3169 casing 1.39 kVrms AC: Between the power supply and the current input terminal/external interface terminal Power supply voltage rating 100 to 240 V AC, 50/60 Hz Maximum rated power 30 VA Dimensions and weight Approx.210(8.27″)W × 160(6.30″) H × 60D(2.36″) mm (excluding protrusions), Approx.1.2 kg(42.3oz.) (3169-20, 3169-21) Conforming standards Safety EN61010 Pollution degree 2,                     measurement    category    Ⅲ    (anticipated    transient    overvoltage    6000V): EMC EN61326 EN61000 - 3 - 2, EN61000 - 3 - 3     For full Hioki 3169 product specifications, please click here: Hioki 3169 Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR's, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our Ebay Test Equipment Store. All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don't hesitate to contact us for a Quote on Something you don't see in our inventory, sometimes we have items that may have not been listed or processed yet. Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment. Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more! We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don't have a listing for a particular item that you are looking for. Please contact us as it may be fresh inventory waiting to be listed or we'll be glad to find it for you at the best price possible and put up an eBay listing for you! We Ship World Wide! We will attempt to ship your item(s) within 24 hours after payment has been received. To get a real-time shipping quote to your destination, enter your country and zip / postal code information into the shipping calculator and click "Get Rate".Many countries impose their own customs, duties, tariffs, taxes, etc. on items being shipped from a foreign country. We do not cover those cost's and we recommend that you contact your countries customs agency for that information.We Offer Multiple Quantity Price & Shipping Discounts, Email Us If You Are Interested In Larger Quantities. We accept credit card payment transactions via the online checkout system! The checkout process is designed so that it communicates with the merchant to confirm that payment has been made and cleared. Other methods of payment are outlined through the online checkout process. Winning bidders must contact us within 3 days after auction close if special payment arrangements are needed. Your payment is expected within 5 days after the auction close. Unpaid auctions will be forfeited after 5 days of the auction close and the Item(s) will be relisted for sale. Items will be shipped within 24 hours (1 Business Day) upon receipt of payment from the winning bidder. (Certain orders may take longer for processing due to comprehensive final service inspections) A Shipment Tracking number(s) will be provided to inform Buyers of their expected ETA (Estimated Time of Arrival). Tracking number(s) will be provided the same day as order shipment. Thank you ALL MAJOR CREDIT CARDS & PayPal ACCEPTED Sell Smarter with Kyozou.Inventory and Ecommerce Management

Price: 1999 USD

Location: Toledo, Ohio

End Time: 2024-03-28T13:52:23.000Z

Shipping Cost: N/A USD

Product Images

Hioki 3169-20 Clamp On Power HiTester Power Quality Analyzer 3169Hioki 3169-20 Clamp On Power HiTester Power Quality Analyzer 3169Hioki 3169-20 Clamp On Power HiTester Power Quality Analyzer 3169Hioki 3169-20 Clamp On Power HiTester Power Quality Analyzer 3169Hioki 3169-20 Clamp On Power HiTester Power Quality Analyzer 3169Hioki 3169-20 Clamp On Power HiTester Power Quality Analyzer 3169Hioki 3169-20 Clamp On Power HiTester Power Quality Analyzer 3169Hioki 3169-20 Clamp On Power HiTester Power Quality Analyzer 3169Hioki 3169-20 Clamp On Power HiTester Power Quality Analyzer 3169Hioki 3169-20 Clamp On Power HiTester Power Quality Analyzer 3169Hioki 3169-20 Clamp On Power HiTester Power Quality Analyzer 3169Hioki 3169-20 Clamp On Power HiTester Power Quality Analyzer 3169

Item Specifics

Restocking Fee: No

Return shipping will be paid by: Buyer

All returns accepted: Returns Accepted

Item must be returned within: 30 Days

Refund will be given as: Money back or replacement (buyer's choice)

Brand: Hioki

MPN: Does not apply

Model: 3169-20

Recommended

Hioki 3280-10F Digital Clamp Hitester 1000A AC Tester Meter
Hioki 3280-10F Digital Clamp Hitester 1000A AC Tester Meter

$72.00

View Details
HIOKI micro-resistance meter RM3548 Unit only
HIOKI micro-resistance meter RM3548 Unit only

$725.95

View Details
Hioki P2000 DC High Voltage Probe, CAT III 2000V CATIV 1000V
Hioki P2000 DC High Voltage Probe, CAT III 2000V CATIV 1000V

$154.00

View Details
HIOKI test lead L9787 NEW From JAPAN
HIOKI test lead L9787 NEW From JAPAN

$36.07

View Details
Hioki 3280-10F Digital Clamp Hitester 1000A AC Tester Meter - Fedex Tracking
Hioki 3280-10F Digital Clamp Hitester 1000A AC Tester Meter - Fedex Tracking

$67.89

View Details
HIOKI DT4282 dt4282 Digital Multimeter 10A Terminal Mounted Type GoodDesign New
HIOKI DT4282 dt4282 Digital Multimeter 10A Terminal Mounted Type GoodDesign New

$388.99

View Details
HIOKI DT4256 Digital Multimeter Highest function / General-purpose type with 10A
HIOKI DT4256 Digital Multimeter Highest function / General-purpose type with 10A

$169.63

View Details
Test Leads + Soft Case for Multimeter Hioki DT4281 DT4282 DT4222 DT4261 DT4255
Test Leads + Soft Case for Multimeter Hioki DT4281 DT4282 DT4222 DT4261 DT4255

$32.29

View Details
Hioki 9669 Clamp On Sensor
Hioki 9669 Clamp On Sensor

$200.00

View Details
New HIOKI C0202 Carrying Case for Digital Multimeter Tachometers
New HIOKI C0202 Carrying Case for Digital Multimeter Tachometers

$45.03

View Details