Description: Portable Multi-parameter Patient Monitor is adaptable to adult, pediatric and neonatal usage. It can monitor vital signals as ECG, Respiratory Rate, SpO2, NIBP, TEMP and IBP.It integrates parameter measuring modules, display and recorder in one device, featuring in compactness, lightweight and portability. Replaceable built-in battery facilitates transportation of patient. Features: 12" high resolution color TFT LCD display. 6 Standard parameters:ECG, RESP, NIBP, SPO2, TEMP, PR. Can be arbitrarily set the alarm limit, automatic sound and light alarm. The back of the machine is designed with a storage box, which can put some accessories,convenient?for doctors use. Drug solubility calculation function, Arrhythmia analysis function. Built-in lithium battery,AC and DC,can provide long-term monitoring after power failure. Widely used in the Department of internal medicine, Dental practices (both pediatric and adult), oral surgery centers surgery, operation room,obstetrics and Gynecology, pediatrics, emergency center,ICU,CCU. Specification: ECG Lead Mode:5 Leads (?R, L, F, N, C or RA, LA, LL, RL,V) Lead selection:I, II, III, avR, avL, avF, V, Waveform:2 ch Lead mode:3 Leads ( R, L, F or RA, LA, LL) Lead selection:I, II, III, Waveform:1 ch Gain:′2.5mm/mV, ′5.0mm/mV, ′10mm/mV, ′20mm/mV, auto HR and Alarm? Range:? Adult:15 ~ 300 bpm Neo/Ped:15 ~ 350 bpm Accuracy:± 1% or ± 1bpm,which great Resolution:1 bpm Sensitivity:> 200 (uV P-P) Differential Input Impedance:> 5 MΩ RESPARATION: Method:Impedance between R-F(RA-LL) Differential Input Impedance:>2.5 MΩ Measuring Impedance Range:0.3~5.0Ω Base line Impedance Range:0 – 2.5 ?KΩ Bandwidth:0.3 ~ 2.5 Hz Resp. Rate Measuring and Alarm Range? Adult:0 ~ 120 rpm Neo/Ped:0 ~ 150 rpm Resolution:1 rpm Accuracy:±2 rpm Apean Alarm:10 ~ 40 S NIBP Method:Oscillometric Mode:Manual, Auto, STAT Measuring Interval in AUTO Mode ?1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240,480 (Min) Measuring Period in STAT Mode:5 Min Pulse Rate Range:40 ~ 240 bpm Alarm Type:SYS, DIA, MEAN Measuring and alarm range:??? Adult Mode SYS :40 ~ 270 mmHg DIA :10 ~ 215 mmHg MEAN:20 ~ 235 mmHg Pediatric Mode SYS:40 ~ 200 mmHg DIA:10 ~ 150 mmHg MEAN:20 ~ 165 mmHg Neonatal Mode SYS:40 ~ 135 mmHg DIA:10 ~ 100 mmHg MEAN:20 ~ 110 mmHg Overpressure Protection Adult Mode:297±3 mmHg Pediatric Mode:240±3 mmHg Neonatal Mode:147±3 mmHg SpO2 Measuring Range:0 ~ 100 % Alarm Range:0 ~ 100 % Resolution:1 % Accuracy:????? 70% ~ 100% ?±2 % 0% ?~ ?69% ?unspecified Actualization interval:about 1 Sec. Alarm Delay:10 Sec. Pulse Rate Measuring and Alarm Range:0~254bpm Resolution:1bpm Accuracy:±2bpm I.5TEMP measurement: Channel:1 Measuring and Alarm Range:0 ~ 50 °C Resolution:0.1°C Accuracy:±0.1°C Actualization interval:about 1 Sec. Average Time Constant: Package List: 1×Patient Monitor 1×EKG Lead wire 1×NIBP Cuff 1×NIBP Extension Cable 1×SpO2 Sensor 1×Temp Sensor 1×Ground Cable 5×Electrode 2×Fuse 1×User Manual(CD) Safe product: The following FDA Disclaimer is required for all eBay listing in Healthcare category and is included for REFERENCE: ARTG NO: 278908 ARTG Number: 278908 FDA Disclaimer: Statement: The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.?(The seller name: Helen Zhang,City:Beijing State: Beijing Country: China Telephone number: 86-18730611603) This item has been cleaned and treated according to the manufacturer's instructions.? The Fingertip Pulse-Oximeter is registered on the Australian Register of Therapeutic Goods (ARTG) with the code 136606, and certified by FDA of United States (Premarket Submission Number (510K): K073454 Listing Number: D045684, K082641 Listing Number: D064765, K090671 Listing Number: D078664); and CE Approved, TUV of Europe (Cert.No. : G1 10 02 50972 013). Payment information: PayPal?only. Please pay the money within 5 days after the auction ended. ? Shipping method: All items will be shipped? within 1 business days. More than 200$,Expedited shipping !!! About 3-5 business days!And It takes approximately 15-22 to remote Area . We are not?Responsible for your Customs duty. Terms of sale Warranty: We guarantees new equipment for a period of 24 months . Our company's obligation under this warranty is repairing or replacement. ? Return Policy : If you receive a defective item which you want to return, please contact us within 30 days from the day you receive the item. All return items must be returned with its original packaging and accessories. Feedback: Contact us first before leaving a negative, we will find a solution to meet your requirement and enhance the satisfaction. About us Quality First, Service Excellent, Global Trust! ? We are the manufacturer and distributor of medical equipments for more than 10 years.?If you are interested in the distribution work, please feel free to contact us. We will reply to you within 24 hours.?Please kindly wait for us. Contact us During the duty time ,we can give you a quick respond. If we are out of work ,please kindly be patient and considerable to give us a little more time ,not just leave the neutral or negative feedback without communication ,thank you for your cooperation ! For more information, please feel free to contact us?
Price: 508.94 USD
Location: Monroe Township, New Jersey
End Time: 2024-09-12T18:05:20.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Screen Dimensions: 12 Inch
Uasage: Suitable for adult, pediatric and neonatal patient
Usage: Department of internal medicine
Features: Battery Operated
Warranty: 24 months
Feature 3: Can be arbitrarily set the alarm limit
Technology: Digital
MPN: Does Not Apply
Monitor Parameters: PR
Feature 2: Real-time S-T segment analysis
UPC: 190891578976
Feature 5: with a storage box
Feature 4: automatic sound and light alarm
Feaure 2: pace-maker detection.
Standard configuration: SpO2, PR, NIBP, ECG, RESP, TEMP
function 2: Arrhythmia analysis function
Function 1: Drug solubility calculation function
Feature 6: Built-in lithium battery
Battery: rechargeable lithium battery
Brand: Unbranded
Intended Use/Discipline: Cardiology
Various interfaces:: standard , trend , oxyCRG , NIBP list , big front screen.