Description: DO - Dissolved Oxygen Meter: Designed to fit the needs for the water O2 testing in all types of market: Range 0.0 – 19.9 ppm O2/l , Resolution of 0.1mg/L, Unit gives 1.5% Full Scale Accuracy, Includes a MA840 Polarographic D.O. Probe with 3 Meter Cable, Spare Membranes, Starter Bottle of MA9071 Electrolyte Solution, Screwdriver for Calibration & a 9 V Battery ( Recommended Calibration Procedure is "Open Air" ) Description The Milwaukee MW600 PRO Portable Dissolved Oxygen meter is one of Milwaukee's most popular meters with its reliable and fast operation as well as its accuracy. The Milwaukee PRO DO Meter is preferred by people looking for lab level accuracy without the cost. The Milwaukee DO Meter is popular with everyone from field biologists and educators to fish farmers and koi pond owners. Design features Fast, easy-to-read results with large digital LCD readout Repeatable, accuracy to ±1.5% FS Lightweight and portable Simple 2 point open air calibration (see video below) Uses MA840 reinforced polarographic probe with an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor 5 o-rings, membranes and one protective cap included 10 feet probe cable for extra flexibility when testing 70 hours of battery life with continuous use (battery included) with low battery warning Care and Use “Open Air” Calibration Procedure 1. Remove the membrane Take the membrane off the end of the probe and dry the diode off. 2. Zero out the display Connect the probe to the base unit and turn the unit on. Your display should read 0.0. If it does not, go to the position “0” screw on the front of the unit with the screw driver provided and through the access hole make the unit display read 0.0. 3. Fill the membrane Go to the membrane and put the “O” ring inside the membrane on the shoulder at the base of the threads. Fill the membrane to just short of the “O” ring with MA9071 electrolyte solution. Be sure that there are no bubbles inside the membrane. (Air bubbles are the main cause of calibration failure) 4. Attach the membrane Screw the membrane on to the probe. 5. Let stablize Turn the meter on and hang the probe off the end of a table pointing down and let the unit display stabilize (this may take 5 to 15 minutes) 6. Adjust Push down and hold the “Cal” button on the front face of the meter and with the screwdriver go to the front Cal position “100%” and make the display read 100. You are now calibrated. Extra tips Watch for the membrane having wrinkles or stretch marks. If you see wrinkles, replace with a new membrane. Always use fresh electrolyte solution (MA9071). Specifications O2 Range: 0.0 to 19.9 mg/L O2 resolution: 0.1 mg/L O2 Accuracy: ±1.5% Full Scale Calibration: Manual on 2 points (zero and slope) Temperature Compensation: Automatic, from 0 to 30°C Probe: MA840 refillable polargraphic probe included Probe Length: MA840 has a 10' cable Membranes: 5 included Environment: 0 to 50°C / 32 to 122°F; max RH 95% Battery Type: 1 x 9V alkaline (included) Battery Life: Approx. 70 hours of continuous use Dimensions: 5.7 x 3.1 x 1.6 inches Weight: 7.5 ounces with battery
Price: 286 USD
Location: Elgin, South Carolina
End Time: 2024-08-17T21:41:31.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Milwaukee
Model: AQ600
MPN: AQ600